About Suppliers

Easy Kleen Pressure Systems Ltd
About Easy Kleen Pressure Systems Ltd, Supplier, Exporter of Electric Cold Water Commercial Pressure Washers, Fill & Play Pressure Washer, Gas Powered Trailer Jetters from New Brunswick, Canada.
About Tote Box Washers
Multi – Stage
- First Stage: Pre Rinse – pumped from third stage rinse tank – drained to Plant drain.
- Second Stage: Wash – Pressurized high volume hot chemical. Wash-recycled through filter and steam heated tank.
- Third Stage: Clean Rinse – Pressurized high volume Rinse – recycled through filter and cold water tank.
- Fourth Stage: Sanitized – main pressure injection of chlorine up to 200 PPM and drain to plant.
Conveyor System:
- Dual 2060 stainless steel conveyor chain run in nylon grooves. (Optional third length chain system)
- SS drive shafts and sprockets.
- Nylon flanged type sealed bearings.
- Adjustable chain speed controller.
- SS 304 square tubing and angle framework.
- SS 11 and 16 gauge shrouding and sheet metal work.
- Poly Neoprene curtains between stages and on each end.
- Tension adjuster.
- Adjustable guild rails for different size tote and tray.
Nozzle Manifold System:
- All stainless steel nozzles and manifold piping.
- SS adjustable angle ball-joint.
- High Impact inner tote cleaning nozzle.
- Easily adjustable to height of container for maximum impact.
- Rugged access doors for easy maintenance.
Pumps Systems:
- Industrial grade continuous duty.
- Seal less, vertical pump designed for no maintenance.
- Proven in pumping high volume high temperature chemicals and dirty fluids.
- TEFC, 575 Volt, 3 Phase Motors.
- Wash stage pump – 10 HP, 175 GPM, 70 PSI.
- Clean rinse stage pump – 7.5 HP, 125 GPM, 70 PSI.
Tanks System
First Stage:
- Drip Tray catches all sprayer debris and drained fitting to connect to plant drains.
Second Stage:
- 175 Gallon SS insulated tank.
- SS Steam heating manifold.
- (Optional) 40 KW 600 volt electrically heated tank
- Temperature controller turns on and off steam valve.
- Temperature gauge.
- Low water pump cut out.
- Automatic refill float valve.
- Large drain valve and sloped for fast and easy wash out.
- Large rectangular filter basked to catch foreign material before being repumped to nozzles.
- (Optional) P.H. controller, sensor and chemical pump to control and maintain chemical strength in tank.)
Third Stage:
- 125 Gallon SS Tank
- Large drain valve and sloped for fast and easy wash out.
- Automatic refill float valve.
- Low water pump cut out.
- Large rectangular basket filter to catch foreign material before being pumped through nozzles.
Fourth Stage:
- Drip tank catches all and drains to plant.
- (Optional) Sanitizer recycle is available, although mostly not recommended, only for iodine base disinfectant.
- (Optional ORP controller, sensor and chemical pump) To control and ensure sanitize strength.
Control Panel:
- Control panel mounted to system.
- Stainless Steel Nema 4 water tight.
- Prewired to all components on system.
- Complete with all necessary starters, overloads, fuses, control transformers, indicator lights and controls as required.
Options (Please Call for Pricing):
- PH – Control System
- ORP – Control System
- Electrically Heated Package – 40KW
- Third Run of Conveyor Chain
- Recycling Sanitizing Pump and Tank System