About Hot Metal Detector
The company is a well-established Exporter and Supplier of Hot Metal Detectors in Canada. The Hot Metal Detector is a photocell sensitive to infrared radiation emitted by metals at a temperature above 250oC as wires, bars and plates etc. A digital output is provided due to the presence of hot metal found, regardless of the section and the position of the metal within the field of view. An analog output proportional to the intensity of the radiation detected metal is available. The special design of the Hot Metal Detector is achieved using microcontrollers last generation, their communication interface RS 485 (optional) and their robust construction make this photocell versatile and ideal for harsh environments such as those found in steel industries. Key Features Of Hot Metal Detectors
- Angle of vertical field of operation : 0o to 30o HMD-DI03865A and 0o to 50o HMD-DI03865B
- Horizontal Field Angle : maximum 3o (adjustable)
- Detection Sensitivity : 1 cm2 to 4 m away to the steel temperature above 250oC
- Response time for detection of material : 2 ms
- Automatic control sensitivity
- Sensitivity adjustment without trimpots
- External control for exchanging isolated sensitivity range for detecting low (Lo)> 400oC and high (Hi)> 250oC
- Four digital outputs solid state
- 0/24 Vdc / 0.1 A with optical isolation related to :
- Inverse detection product
- Direct detection of the product
- Quality of the signal detected
- Fail : for food, internal cooling system, the engine speed and the operation of the microcontroller
- Relay output on the presence of the material : a changeover contact for 5Amax x 250Vac (resistive load) with transient protectors
- Output voltage or current analog, programmable and adjustable trimpots without (0 to 10 Vdc, 0 to 20 mA and
- 4 to 20mA, accuracy of 1% of range) proportional to the intensity of radiation
- Command the test panel and the connector for simulating the presence of hot metal, using infrared photodiode
- Serial communication interface RS485 with MODBUS-RTU (optional)
- Mira positioning laser "Point", activated by the test command
- Two LED displays 7-segment, 3 momentary contact switches and 2 LEDs located on the control panel, protected by a hinged cover, intended for programming, operation, and adjustment of detector sensitivity
- Power Supply : 110/220 Vac - 50 / 60Hz